Specifications
General
Scanning
Full digital beam forming
Frequency
180 kHz
Basic Range
50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 1000, 1200, 1600, 2000 m
95, 190, 285, 380, 475, 570, 665, 760, 855, 950, 1140, 1330, 1520, 1900 m
Off-center
95, 190, 285, 380, 475, 570, 665, 760, 855, 950, 1140, 1330, 1520, 1900 m
Audio Search
1 kHz
10 W (optional speaker required)
Display Unit
Pixel number
SXGA(1280×1024)
Colors
32 colors (sonar pictures), 6 colors (marks)
Head-up, North-up* and Course up*
(*: sensor required)
Display mode
Slant, Vertical combination scan*, Echo sounder
combination*, Vertical and echo sounder combination*
(*: future use)
Additional functions
Water temperature, Wind speed/bearing
Interference rejecter, Afterglow, Noise limiter, Delete
color, Automatic target tracking, Auto-retraction,Fish school alarm
Others
Scan (Bearing/Distance), Cursor
(Distance/Depth/Bearing), Event, Fish school
(Position/Bearing), Own ship’s location, Speed/Bearing
Hull Unit
Raising/Lowering time
8 s (800 mm travel), 11 s (1100 mm travel)
Allowable Ship's Speed
18 kn (15 kn for raise/lower operation)
Transducer Travel
800 mm or 1100 mm
Beam width
Tx, Horizontal: 180°, Vertical: 6° (-3 dB at 180 kHz)
Rx, Horizontal: 6°, Vertical: 6° (-3 dB at 180 kHz)
Interface
Ports
Video output: 2 ch, HDMI, SXGA
NMEA0183: 5 ch, V1.5/2.0/3.0/4.0/4.1
External KP: 1 ch, current loop or contact closure
(Input: 5-15 V, Output: 12 V)
Voice output: 1 ch, 10 W, 4 ohms, monaural
Gyrocompass: 1 ch, AD-10
Echo sounder input: 1 ch, VI-1100A analog
Contact closure: 1 ch, for external switch
USB: USB2.0: 2 ch, USB3.0: 2 ch
LAN: 2 ch, Ethernet, 1000Base-T
NMEA0183
Input: CUR, DBS, DBT, DPT, GGA, GLL, GNS, HDG, HDM,
HDT, MDA, MTW, MWV, RMC, THS, VBW*, VDR, VHW,
VTG, VWR, VWT, ZDA
Output: TLL
*: fore-aft/port-stbd speed data required
Power Supply
Processor Unit
12-24 VDC: 4.0-2.0 A
Transceiver Unit
100/110/115/220/230 VAC, 2.5 A max., 1 phase, 50-60 Hz
Hull Unit
200-220 VAC, 4 A max., 3 phase, 50/60 Hz
Rectifier
100/110/115/220/230 VAC, 1 phase, 50/60Hz
Environment
Temperature
Processor unit: -15°C to +55°C
Transducer: -5°C to +35°C
Transceiver unit: 0°C to +50°C
Matching box: 0°C to +50°C
Hull unit: 0°C to +50°C
Control unit: -15°C to +55°C
Relative humidity
93% or less at +40°C
Waterproofing
Transducer: IPX8
Control unit: IP22 (panel), IP20 (chassis)
Processor unit: IP22
Transceiver unit: IP22
Matching box: IP22
Hull unit: IPX2
Vibration
IEC 60945 Ed.4